MicroTorch gas lighter burner
MicroTorch Type IB
Characteristics:
- Once filled, it lasts for 60 minutes of continuous operation;
- for use in dental and prosthetic offices;
- filled with gas for lighters (propane-butane);
- easy to use;
- achievable temperature 1300 °C;
- 3 months warranty.
Packaging:
- 1pc.
Keystone spirit burner
- Keystone spirit burner.
Advantages:
- The wick is durable and maintains a steady flame.
- Made of durable plastic.
Packaging:
- 1 piece.
Bijou 90 propane-butane table burner
Bijou 90 tabletop laboratory burner.
Renfert catalog number 9600000
Characteristics:
- proven quality and safety thanks to DIN-DVGW type examination certificate in accordance with DIN 30665-1;
- the required flame intensity can be selected steplessly between the main flame and the economy flame;
- the oxygen supply is regulated by means of setting rings on the chimney;
- each burner, in addition to the vertical position, can be tilted in any direction by 30 degrees;
- this prevents dripping wax from clogging the nozzle;
- the burner can be easily disconnected from the non-tip base;
- propane-butane gas burner;
- 3-year warranty.
Technical Data:
- temperature range (max. ambient temperature) 40°C;
- weight 530 g;
- dimensions (width x height x depth) 100 x 109 x 60 mm;
- diameter (nozzle) 0.34 mm;
- connection pressure 50 mbar;
- height (depending on angle) 102 - 109 mm;
- connection hose (standard) DIN 30664;
- gas consumption: 48 g/h;
- type of gas: liquefied petroleum gas.
Packaging:
- 1 pc.
Gas for Microtorch burners 300ml
Gas for piezoelectric burners and lighters
Characteristics:
- aluminum can contains highly refined butane intended for refilling various types of lighters;
- each gas container is equipped with a set of tips for various types of lighter valves;
- the applicator placed in the container has a universal, conical shape that fits almost all types of lighters in the world.
Packaging:
- 300ml
Bunsen Burner with Valve and Pilot Flame - Natural Gas
Natural gas benchtop laboratory burner.
The rubber base must be purchased separately! micran code 3306
Description:
- air regulation;
- flame regulating tap;
- pilot flame inside.
Attention:
Burners complying with DIN 30665 cannot be switched off completely.
A small flame continues to burn even after the needle valve or shut-off tap is closed.
The gas supply should be shut off using the central shut-off tap in the laboratory.
Packaging:
- 1pc.
Bunsen burner with valve and pilot flame - propane-butane gas
Laboratory table burner for propane-butane gas.
The rubber base must be purchased separately! micran code 3306
Description:
- air regulation;
- flame regulating tap;
- pilot flame inside.
Attention:
Burners complying with DIN 30665 cannot be switched off completely.
A small flame continues to burn even after the needle valve or shut-off tap is closed.
The gas supply should be shut off using the central shut-off tap in the laboratory.
Packaging:
- 1pc.
Rubber base for gas bunsen burners
Rubber base for the burner, provides better grip on the surface.
Packaging:
- 1pc
ECO burner with ignition fuse
New burner with ignition fuse.
Renfert catalog number 9340100
Advantages:
- nozzle inclined 60 degrees;
- automatic shut-off of the gas supply when the flame goes out;
- easy-to-clean wax tank;
- 36-month warranty.
Technical Data:
- for liquefied petroleum gas (propane-butane);
- connection hose (standard): DIN 30664;
- supply pressure: 50 mbar (0.725 psi);
- Ø (nozzle) 0.34 mm
- consumption: 50 g/h (1.76 oz/h);
- ambient temperature max. 40°C;
- dimensions (W x H x D) 141 x 102 x 121 mm;
- weight ~460 g
Packaging:
- 1 pc.
Bijou 90 natural gas table burner
Bijou 90 tabletop laboratory burner.
Renfert catalog number 9610000
Characteristics:
- proven quality and safety thanks to DIN-DVGW type examination certificate in accordance with DIN 30665-1;
- the required flame intensity can be selected steplessly between the main flame and the economy flame;
- the oxygen supply is regulated by means of setting rings on the chimney;
- each burner, in addition to the vertical position, can be tilted in any direction by 30 degrees;
- this prevents dripping wax from clogging the nozzle;
- the burner can be easily disconnected from the non-tip base;
- consumption: 63 l/h (2.2 ft³/h);
- 3-year warranty.
Technical Data:
- temperature range (max. ambient temperature): 40°C;
- weight: 530 g;
- dimensions (width x height x depth): 100 x 109 x 60 mm;
- diameter (nozzle): 0.55 mm;
- connection hose (standard): DIN 30664;
- supply pressure: 20 mbar;
- gas consumption: 63 l/h (2.2 ft³/h);
- gas type: natural gas.
Packaging:
- 1 pc.
Microtorch Type II torch - round base
MicroTorch gas burner with piezo ignition for lighters. Equipped with a safe switch lock and flame size adjustment.
Characteristics:
- Burner for use in the dental and prosthetic office.
- Gas filling burner for lighters (propane-butane)
- Easy to use
- Achievable temp. 1300 °C
- 3 months warranty
Packaging:
- 1 piece.
Microtorch Type III
MicroTorch piezo ignition burner for lighter gas.
Equipped with a safe switch lock and flame size adjustment.
Characteristics:
- modern MicroTorch burner with reinforced construction;
- the maximum filling of the tank is enough for 30 minutes of continuous operation;
- burner for use in dental and prosthetic offices;
- gas refill burner for lighters (propane-butane);
- easy to use;
- achievable temperature 1300 °C;
- 3 months warranty.
Packaging:
- 1 pc.
Bunsen burner with needle valve - natural gas
Bunsen burner with needle valve - natural gas.
The rubber base must be purchased separately! micran code 3306
Attention:
DIN burners cannot be completely switched off according to standard 30665.
Therefore, a small flame burns even when the needle valve is closed.
For safety reasons, the user is forced to cut off the gas supply to the laboratory burners at a mandatory central, stationary cut-off point in the laboratory.
Packaging:
- 1pc.
Bunsen burner with needle valve - propane/butane
Bunsen burner with needle valve - propane/butane.
The rubber base must be purchased separately! micran code 3306
**Attention:*
DIN burners cannot be completely switched off according to standard 30665.
Therefore, a small flame burns even when the needle valve is closed.
For safety reasons, the user is forced to cut off the gas supply to the laboratory burners at a mandatory central, stationary cut-off point in the laboratory.
Packaging:
- 1pc
Microtorch Type I gas lighter burner
State-of-the-art piezo ignition system.
Air and gas flow adjustment knobs provide excellent flame control.
Large butane chamber provides hours of use.
Characteristics:
- Once filled, it lasts for 60 minutes of continuous operation;
- for use in dental and prosthetic offices;
- filled with lighter gas (propane-butane);
- easy to use;
- achievable temperature approx. 1300 °C (2500 °F);
- 3 months warranty.
Packaging:
- 1pc.